Maintenance 81
11.1. Warning Pause
Displays the list of warning and warning signals that are occurring or paused.
Usually, the alarm of consumption degree calculation is notified at the intervals you set.
If you desire to stop notification (alarm, dedicated output signal), you can temporarily disable at this stage.
Note that the alarm of abnormality detection cannot be reset while it exceeds the notification level.
1) Component/Axis Number:
Indicates the parts and axes currently under warning.
2) Warning:
Indicates either occurring or pause.
Select this check box to pause. Deselect this check box to cancel pause.
3) Signal Output:
Indicates either occurring or pause.
Select this check box to pause. Deselect this check box to cancel pause.
4) Pause Method of Warning Occurrence / Signal Output:
Set the pause method of warning occurrence.
5) Write:
Writes the content of the selected item.
You can temporarily disable notification related to consumption degree calculation until part
replacement (reset of consumption degree).
You can also temporarily disable notification related to abnormality detection.
6) Update:
Updates the screen display.
(4) Pause Method of Warning
Occurrence / Signal Output
(2) Warning
Warning Pause screen
Warning Pause
(6) Update
(5) Write
(1) Component/Axis Number
(3) Signal Output
Even though you set pause of warning occurrence or signal output, already occurred
warnings and warning signals are not reset.
Use the error reset operation from the teaching pendant or inputting error reset signal
(ERRRESET) to reset those warnings and signals.