EasyManua.ls Logo

Mitsubishi Electric EZMOTION MR-E Super MR-E-70A-QW003 - Gain Changing Function

Mitsubishi Electric EZMOTION MR-E Super MR-E-70A-QW003
326 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 - 5
8. SPECIAL ADJUSTMENT FUNCTIONS
8.5 Gain changing function
This function can change the gains. You can change between gains during rotation and gains during stop or
can use an external input signal to change gains during operation.
8.5.1 Applications
This function is used when.
(1) You want to increase the gains during servo lock but decrease the gains to reduce noise during rotation.
(2) You want to increase the gains during settling to shorten the stop settling time.
(3) You want to change the gains using an external input signal to ensure stability of the servo system since
the load inertia moment ratio varies greatly during a stop (e.g. a large load is mounted on a carrier).
8.5.2 Function block diagram
The valid control gains PG2, VG2, VIC and GD2 of the actual loop are changed according to the conditions
selected by gain changing selection CDP (parameter No.65) and gain changing condition CDS (parameter
No.66).
Valid
GD2 value
Command pulse
frequency
Droop pulses
Model speed
External input
signal CDP
Comparator
Valid
PG2 value
Valid
VG2 value
Valid
VIC value
Changing
PG2 PG2B
100
VIC VICB
100
VG2 VG2B
100
GD2B
Parameter No.61
GD2
Parameter No.34
PG2
Parameter No.35
VG2
Parameter No.37
VIC
Parameter No.38
CDP
Parameter No.65
CDS
Parameter No.66
www.DataSheet4U.com

Table of Contents

Related product manuals