INVERTER
INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)
J
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
IB(NA)-0600503ENG-J(1705)MEE Printed in Japan Specifications subject to change without notice.
FR-A800
INSTRUCTION MANUAL (DETAILED)
FR-A820-00046(0.4K) to 04750(90K)(-GF)
FR-A840-00023(0.4K) to 06830(280K)(-GF)
FR-A842-07700(315K) to 12120(500K)(-GF)
FR-A846-00023(0.4K) to 03610(132K)
High functionality and high performance
MODEL
FR-A800
INSTRUCTION MANUAL
MODEL
CODE
XXX-XXX
Model
FR-A800
Instruction Manual (Detailed)
Model code 1A2-P52

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-A840-02160 (75K) Specifications

General IconGeneral
Model NumberFR-A840-02160 (75K)
SeriesFR-A840
Power Rating75 kW
Output Current160 A
Cooling MethodForced air cooling
Enclosure RatingIP20
Control MethodVector control
Frequency Range0 to 400 Hz
Protection FeaturesOvercurrent, Overvoltage, Undervoltage
Operating Temperature-10°C to +50°C
Storage Temperature-20 to +65 °C
Humidity5 to 95 %RH (Non-condensing)
AltitudeUp to 1000 m above sea level

Summary

Chapter 1 Introduction

1.1 Product checking and accessories

Verify the inverter model and rating plate to ensure model agreement with the order and product integrity.

Chapter 2 Installation and Wiring

2.3 Installation of the inverter and enclosure design

Guidelines for determining the structure, size, and device layout of the inverter enclosure.

2.4 Terminal connection diagrams

Illustrates the wiring diagrams for various inverter connection types, including main and control circuits.

2.5 Main circuit terminals

Details the specifications and functions of the main circuit terminals.

2.6 Control circuit

Explains the wiring and functions of the control circuit terminals.

Chapter 3 Precautions for Use of the Inverter

3.1 Electro-magnetic interference (EMI) and leakage currents

Discusses EMI countermeasures, leakage currents, and their suppression techniques.

3.4 Power shutdown and magnetic contactor (MC)

Recommends providing an MC on the inverter's input side for safety and maintenance.

3.6 Checklist before starting operation

A checklist of points to verify before starting inverter operation to prevent product damage or life reduction.

3.7 Failsafe system which uses the inverter

Explains the use of inverter status output signals to provide an interlock for detecting inverter failures.

Chapter 4 Basic Operation

4.1 Operation panel (FR-DU08)

Details the components and functions of the FR-DU08 operation panel.

4.5 Basic operation procedure (PU operation)

Provides step-by-step instructions for basic operation using the PU (operation panel).

4.6 Basic operation procedure (External operation)

Provides step-by-step instructions for basic operation using external signals.

Chapter 5 Parameters

5.1 Parameter list

Provides a comprehensive list of all inverter parameters, their initial values, and settings range.

5.2 Control method

Explains the available control methods: V/F, Advanced magnetic flux vector, Real sensorless vector, Vector, and PM sensorless vector control.

5.3 Speed control under Real sensorless vector control, vector control, PM sensorless vector control

Details speed control adjustments for Real sensorless vector, Vector, and PM sensorless vector control.

5.10 (H) Protective function parameter

Details protective functions such as overload, overvoltage, and phase loss protection.

Chapter 6 Protective Functions

6.5 Causes and corrective actions

Troubleshooting guide for various error messages, warnings, and alarms.

6.6 Check first when you have a trouble

A troubleshooting guide for common issues like motor not starting or abnormal noise.

Chapter 7 Precautions for Maintenance and Inspection