How to fix ground fault on Mitsubishi Electric FR-E740-040 Inverter?
- KKathleen KingSep 6, 2025
To fix a ground fault on your Mitsubishi Electric Inverter, locate and repair the ground fault.

How to fix ground fault on Mitsubishi Electric FR-E740-040 Inverter?
To fix a ground fault on your Mitsubishi Electric Inverter, locate and repair the ground fault.
What to do for Mitsubishi Electric FR-E740-040 reset?
To resolve an unexpected inverter reset on your Mitsubishi Electric Inverter, turn off the reset command.
What to do if Mitsubishi Electric FR-E740-040 Inverter shows input phase loss?
If your Mitsubishi Electric Inverter indicates an input phase loss: * Ensure the cables are wired correctly. * Repair any breaks in the cable. * Verify the Pr. 872 Input phase loss protection selection setting.
How to resolve motor overload trip (electronic thermal relay function) on Mitsubishi Electric Inverter?
To address a motor overload trip (electronic thermal relay function) on your Mitsubishi Electric Inverter: 1. Reduce the load weight. 2. If using a constant-torque motor, configure Pr. 71 Applied motor to indicate a constant-torque motor.
How to resolve Mitsubishi Electric Inverter overload trip (electronic thermal relay function)?
To resolve an inverter overload trip (electronic thermal relay function) on your Mitsubishi Electric Inverter: 1. Reduce the load weight. 2. Ensure the ambient temperature is within specified limits.
What to do if Mitsubishi Electric Inverter shows undervoltage?
If your Mitsubishi Electric Inverter is showing an undervoltage error, check the power supply system equipment, including the power supply itself.
What to do for regenerative overvoltage trip during acceleration on Mitsubishi Electric Inverter?
To resolve regenerative overvoltage trip during acceleration on your Mitsubishi Electric Inverter: 1. Decrease the acceleration time. 2. Ensure that the regeneration avoidance function (Pr. 882, Pr. 883, Pr. 885, Pr. 886) is enabled and properly configured.
Why is Mitsubishi Electric FR-E740-040 Inverter showing electronic thermal relay function prealarm?
If your Mitsubishi Electric Inverter is showing an electronic thermal relay function prealarm: 1. Reduce the load and frequency of operation. 2. Set an appropriate value in Pr. 9 Electronic thermal O/L relay.
What to do if Mitsubishi Electric FR-E740-040 Inverter shows regenerative brake prealarm?
If you're seeing a regenerative brake prealarm on your Mitsubishi Electric Inverter: 1. Try increasing the deceleration time. 2. Make sure that the Pr. 30 Regenerative function selection and Pr. 70 Special regenerative brake duty settings are configured correctly.
How to fix write disable error on Mitsubishi Electric FR-E740-040?
A write disable error on your Mitsubishi Electric Inverter may occur due to several reasons: * If Pr. 77 Parameter write selection is set to disable parameter write, check this setting. * If the frequency jump setting range is overlapping, review the settings of Pr. 31 to Pr. 36 (frequency jump). * If the PU and inverter are not communicating correctly, verify the connection between the PU and the inverter.
| Brand | Mitsubishi Electric |
|---|---|
| Model | FR-E740-040 |
| Category | Inverter |
| Language | English |
Explains the general characteristics and installation requirements of the FR-E700 series inverter.
Covers terminal connections, specifications, and wiring guidelines for main and control circuits, plus option units.
Details critical safety information, EMC measures, installation guidelines, and failsafe system configurations.
Provides a comprehensive guide to inverter parameters, operation modes, motor settings, and special functions.
Offers guidance on resetting protective functions, identifying faults, causes, and corrective actions for common issues.
Outlines essential maintenance procedures, inspection items, and part replacement guidelines for long-term reliability.
Lists the technical specifications of the inverter, including ratings, common specs, and outline dimension drawings.
Contains supplementary information, including comparisons with previous models, specification changes, and an index.












Loading...