4.2.9 Illustration: Guided Ladder Entry Mode
In addition to the freehand ladder entry methods, GX IEC Developer Version 6 onward features
a
Guided Ladder Entry
Monitor method which may be used to aid Ladder program entry. This
entry method may prove to be helpful to those wishing to make the transition to GX-IEC Devel
-
oper who have had previous familiarity with Mitsubishi’s MEDOC package and GX-Developer.
Enter the
Guided Entry Monitor
mode by pressing the button on the tool bar. The
following matrix is placed into the edit area:
Use the following buttons on the toolbar to select the ladder symbols. The corresponding
number may be pressed to select the appropriate symbol from the keyboard, thus eliminat
-
ing the need to use the mouse:
Select the ‘Normally Open’ Contact symbol “1” and the following will be displayed:
The program may continue to be entered using the “F2” button on the keyboard or click on the
button on the tool bar to call up the variables selection window as previously described.
4-36 MITSUBISHI ELECTRIC
Building a Project Application Program