Appendix C: Differences with FX2N-1PG
Appendix C-2 Differences of Buffer Memory
130
FX3U-1PG User's Manual
Appendix C-2 Differences of Buffer Memory
BFM No.
Item
Setting range
High
order
16bit
Low
order
16bit
FX3U-1PG FX2N-1PG
- #0 Pulse rate 1 to 32,767 PLS/REV
#2 #1 Feed rate 1 to 2,147,483,647 (user unit) 1 to 999,999 (user unit)
- #3 Operation parameter
b1, b0: System of units
b3, b2: Interrupt input setting b3, b2: Not used
b5, b4: Position data multiplier
b6: Acceleration/deceleration mode b6: Not used
b7: Variable speed operation acceleration/
deceleration setting
b7: Not used
b8: Pulse output format
b9: Rotation direction
b10: Zero return direction
b11: Limit deceleration mode b11: Not used
b12: DOG input polarity
b13: Count start point
b14: STOP input polarity
b15: STOP input mode
#5 #4 Maximum speed
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
1 to 153,000 (user unit)
Set the value within 10 to 100,000 Hz
when converted to pulse data.
- #6 Bias speed
0 to 32,767 (user unit)
Set the value within 0 to 200,000 Hz when
converted to pulse data.
0 to 15,300 (user unit)
Set the value within 0 to 10,000 Hz when
converted to pulse data.
#8 #7 JOG speed
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
1 to 153,000 (user unit)
Set the value within 10 to 100,000 Hz
when converted to pulse data.
#10 #9
Zero return speed
(high speed)
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
1 to 153,000 (user unit)
Set the value within 10 to 100,000 Hz
when converted to pulse data.
-#11
Zero return speed
(creep)
1 to 32,767 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
1 to 15,300 (user unit)
Set the value within 0 to 10,000 Hz when
converted to pulse data.
-#12
Number of zero-point
signal for zero return
0 to 32,767
#14 #13 Zero-point address
-2,147,483,648 to 2,147,483,647 (user
unit)
Set the value within -2,147,483,648 to
2,147,483,647 PLS when converted to
pulse data.
-999,999 to 999,999 (user unit)
Set the value within -999,999 to 999,999
PLS when converted to pulse data.
-#15
Acceleration/
deceleration time
Trapezoidal acceleration/deceleration:
1 to 32,767 ms
Approximate S-shaped acceleration/
deceleration:
1 to 5,000 ms
Trapezoidal acceleration/deceleration:
50 to 5,000 ms
- #16 Starting delay time 0 to 1,000 ms Not used
#18 #17 Target address Ι
-2,147,483,648 to 2,147,483,647 (user
unit)
Set the value within -2,147,483,648 to
2,147,483,647 PLS when converted to
pulse data.
-999,999 to 999,999 (user unit)
Set the value within -999,999 to 999,999
PLS when converted to pulse data.
#20 #19 Operation speed Ι
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
1 to 153,000 (user unit)
Set the value within 10 to 100,000 Hz
when converted to pulse data.
#22 #21 Target address ΙΙ
-2,147,483,648 to 2,147,483,647 (user
unit)
Set the value within -2,147,483,648 to
2,147,483,647 PLS when converted to
pulse data.
-999,999 to 999,999 (user unit)
Set the value within -999,999 to 999,999
PLS when converted to pulse data.