#24 #23 Operation speed ΙΙ
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
1 to 153,000 (user unit)
Set the value within 10 to 100,000 Hz
when converted to pulse data.
- #25 Operation command
b0: Error reset
b1: STOP
b2: Reverse limit
b3: Reverse limit
b4: Forward JOG operation
b5: Reverse JOG operation
b6: DOG type mechanical zero return operation start
b7: Relative/absolute address
b8: 1-speed positioning operation start
b9: Interrupt 1-speed positioning operation start
b10: 2-speed positioning operation start
b11: External command positioning operation start
b12: Variable speed operation
b13: Interrupt stop operation start b13: Not used
b14: Interrupt 2-speed positioning
operation start
b14: Not used
b15: Data-set type mechanical zero return
operation start
b15: Not used
#27 #26 Current address -2,147,483,648 to 2,147,483,647 (user unit)
- #28 Status information
b0: READY
b1: Forward/Reverse
b2: Zero return completion
b3: STOP input ON
b4: DOG input ON
b5: PG0 input ON
b6: Current value overflow
b7: Error flag
b8: Positioning completion flag
b9: 1-speed completion flag b9: Not used
b10: Interrupt input 0 ON b10: Not used
b11: Interrupt input 1 ON b11: Not used
b12: Remaining distance operation waiting b12: Not used
b13 to b15: Not used
- #29 Error code An error code is stored at the time of the error occurrence.
- #30 Model code K5,130 K5,110
- #31 Not used Not used
Buffer memories BFM#32 and later are new in the FX3U-1PG.
Refer to Section 7.2 for the contents of buffer memories BFM#32 and later.
Not used
BFM No.
Item
Setting range
High
order
16bit
Low
order
16bit