7 Buffer Memory
7.4 Control Data
75
FX3U-1PG User's Manual
1
Introduction
2
Specification
3
System
Configuration
4
Installation
5
Wiring
6
Before Starting
Positioning
Operation
7
Buffer Memory
8
Manual Control
9
Positioning
Control
10
Program
Example
*1. Timing of detection.
Level detection: activated when the bit is set or cleared.
Edge detection: activated at OFF-to-ON transition.
Point
The priority order of each bit becomes as follows. When several bits are turned on, the bit with higher
priority becomes valid. However, if several bits of the positioning operations (b6, b8 to b15) turn on, the
operation is not executed, and the operation command multiple selection error occurs.
When another operation command is turned on during operation, the operation command turned on later is
ignored, and no error will occur.
Create the sequence program as each bit (b0, b6, b8 to b11, b13 to b15) of the edge detection always
turns off after being turned on. Without turning off each bit, the second or further operations cannot be
executed.
Error reset (b0) is executed only when an error is occurring.
Do not use the forward limit (b2)/reverse limit (b3) for any purposes other than limiting.
The positioning operations (b6, b8 to b15) become valid when all bits of the BFM#25 (b0 in the normal
status, excluding the b2/b3 and b7 opposite from the operation direction) are turned off and then on.
7.4.7 [BFM#54, #53] Target address change value
Set the target address change value that is used in the target address change function.
For details on the target address change function, refer to Section 6.7.
Point
Value is in user units and includes the position data multiplier.
-#25
b13
Interrupt stop
operation start
When it is turned on, the interrupt stop operation
starts.
For details on the interrupt 1-speed
positioning operation, refer to Section 9.7.
Edge
H0000b14
Interrupt 2-speed
positioning
operation start
When it is turned on, the interrupt 2-speed
positioning operation starts.
For details on the interrupt 2-speed
positioning operation, refer to Section 9.8.
Edge
b15
Data-set type
mechanical zero
return operation
start
When it is turned on, the data-set type mechanical
zero return operation starts.
For details on the data-set type mechanical
zero return operation, refer to Subsection 8.3.3.
Edge
Priority high Priority low
Error reset (b0) > Forward/reverse limit (b2, b3) > STOP (b1) > Forward JOG/reverse JOG (b4, b5) > Positioning operation (b6, b8 to b15)
BFM No.
Description R/W Default
High order
16bit
Low order
16bit
#54 #53
Setting range: -2,147,483,648 to 2,147,483,647 (user unit)
The value must be within the range from -2,147,483,648 to 2,147,483,647 PLS when
converted to pulse data.
R/W K0
BFM No.
Bit
No.
Item Description
Detection
*1
Default
High order
16bit
Low order
16bit