7 Buffer Memory
7.4 Control Data
76
FX3U-1PG User's Manual
7.4.8 [BFM#56, #55] Operation speed change value
Set the operation speed change value that is used in the operation speed change function.
For details on the operation speed change function, refer to Section 6.6.
*1. In case of external command positioning operation
-2,147,483,647 to -1, 1 to 2,147,483,647 (user unit). Set the value within -200,000 to -1, 1 to 200,000
Hz when converted to pulse data.
7.4.9 [BFM#57] Operation command ΙΙ
A list of operation command II is as shown in the following table.
*1. Timing of detection.
Level detection: activated when the bit is set or cleared.
Edge detection: activated at OFF-to-ON transition.
Point
If INT0 (b0) or INT1 (b1) is on when the positioning operation starts, it automatically turns off.
BFM No.
Description R/W Default
High order
16bit
Low order
16bit
#56 #55
Setting range: 1 to 2,147,483,647 (user unit)
The value must be within the range from 1 to 200,000 Hz when converted to pulse
data.
*1
R/W K0
BFM No.
Bit
No.
Item Description
Detection
*1
Default
High order
16bit
Low order
16bit
-#57
b0 INT0
The interrupt input is executed via the PLC (BFM).
INT0 turns on when b0 = ON.
Edge
H0000
b1 INT1
The interrupt input is executed via the PLC (BFM).
INT1 turns on when b1 = ON.
Edge
b2 to
b15
- Not used - -