EasyManua.ls Logo

Mitsubishi Electric FX3U SERIES - CLEAR Signal Output (DSZR;ZRN Instruction

Mitsubishi Electric FX3U SERIES
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
4 Before Programming
4.3 Various Special Relays for Operation Commands
B - 60
4.3.4 CLEAR Signal Output (DSZR/ZRN Instruction)
The DSZR instruction (zero return instruction with DOG search function) and ZRN instruction (zero return
instruction) can stop the workpiece at the origin, and can output the CLEAR signal.
If it is necessary to output the CLEAR signal after zero return, turn on the "CLEAR signal output function
enable" relay. The following table shows the "CLEAR signal output function enable" relay of each pulse
output destination device (Y000, Y001, Y002 and Y003).
Use an FX
3UC PLC Ver. 2.20 or later and FX3S/FX3G/FX3GC/FX3U PLC to specify the CLEAR signal output
device.
For operation of DSZR instruction, refer to Section 6.2.
For operation of ZRN instruction, refer to Section 6.3.
1. If it is not necessary to use the CLEAR signal device specification function, or if an FX3UC PLC
below Ver. 2.20 is used:
*1. Y002 is not available in FX3G PLC (14-point and 24-point type) and FX3S/FX3GC PLC.
*2. Y003 is available only when two high-speed output special adapters are connected to the FX
3U PLC.
2. If it is necessary to use the CLEAR signal device specification function:
Turn on "CLEAR signal device specification function enable" relay to specify the CLEAR signal output device
(output Y) for the pulse output destination device using the CLEAR signal device specification register.
*3. Y002 is not available in FX
3G PLC (14-point and 24-point type) and FX3S/FX3GC PLC.
*4. Y003 is available only when two high-speed output special adapters are connected to the FX
3U PLC.
For the CLEAR signal device specification method, refer to the next page.
When using a high-speed output special adapter:
The output devices initially set for the CLEAR signal of the DSZR/ZRN instruction are the same output
devices as the "direction signal / reverse pulse train (rotation direction signals)" of the high-speed output
special adapters. Be sure to specify output numbers of other transistor outputs using the CLEAR signal
device specification function.
Pulse output
destination
device
Status of "CLEAR
signal output
function enable"
relay
Status of "CLEAR signal
device specification
function enable" relay
CLEAR signal device
number
Y000 M8341=ON M8464=OFF Y004
Y001 M8351=ON M8465=OFF Y005
Y002
*1
M8361=ON M8466=OFF Y006
Y003
*2
M8371=ON M8467=OFF Y007
Pulse output
destination
device
Status of "CLEAR
signal output function
enable" relay
Status of "CLEAR signal
device specification
function enable" relay
CLEAR signal device number
CLEAR signal device
specification register
Initial value (CLEAR
signal device)
Y000 M8341=ON M8464=ON D8464 -
Y001 M8351=ON M8465=ON D8465 -
Y002
*3
M8361=ON M8466=ON D8466 -
Y003
*4
M8371=ON M8467=ON D8467 -