EasyManua.ls Logo

Mitsubishi Electric FX3U SERIES - 4.5 Setting of Various Items on PLC Side; Setting of Common Items Using Program

Mitsubishi Electric FX3U SERIES
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
4 Before Programming
4.5 Setting of Various Items on PLC Side
B - 67
A
Common Items
B
Built-in
Positioning
Functions
Apx.
Example
Connection
4.5 Setting of Various Items on PLC Side
4.5.1 Setting of Common Items Using Program
For each pulse output destination device (Y000, Y001, Y002
*1
, Y003
*2
), set the items shown in the following
table without using the operand of the instruction.
Setting
item
Setting device Instruction
Refer to
Y000 Y001
Y002
*1
Y003
*2
DSZR ZRN ABS
TBL
*3
PLSV
DVIT
*4
DRVI DRVA
Items related to speed
Maximum
speed
*5
D8344,
D8343
D8354,
D8353
D8364,
D8363
D8374,
D8373

-
*6

Subsec-
tion
4.2.5
Bias speed
D8342 D8352 D8362 D8372

-
*6

Subsec-
tion
4.2.6
Acceleration
time
*7
D8348 D8358 D8368 D8378

-
*6

Subsec-
tion
4.2.7
Deceleration
time
*7
D8349 D8359 D8369 D8379

-
*6

Subsec-
tion
4.2.8
Zero return
speed
*5
D8347,
D8346
D8357,
D8356
D8367,
D8366
D8377,
D8376
-------
Subsec-
tion
4.2.3
Creep speed
D8345 D8355 D8365 D8375
-------
Subsec-
tion
4.2.4
Items needed for (DSZR) zero return instruction with DOG search function and (ZRN) zero return instruction)
Zero return
direction
M8342 M8352 M8362 M8372
-
*8
------
Subsec-
tion
4.3.3
CLEAR
signal output
M8341 M8351 M8361 M8371

------
Subsec-
tion
4.3.4
CLEAR
signal device
change
*9
M8464
D8464
M8465
D8465
M8466
D8466
M8467
D8467

------
Subsec-
tion
4.3.4
Logic of
near-point
signal
M8345 M8355 M8365 M8375
-------
Subsec-
tion
4.3.5
Logic of
zero-phase
signal
M8346 M8356 M8366 M8376
-------
Subsec-
tion
4.3.6
Items needed for variable speed pulse output (PLSV) instruction
Acceleration/
deceleration
Operation
*7
M8338
----
---
Subsec-
tion
4.3.9
Items needed for interrupt positioning (DVIT) instruction
*4
Interrupt
input signal
device
change
*10
M8336
D8336
---
*6
-
--
Subsec-
tion
4.3.7