PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
8 1-Speed Positioning - DRVI/DRVA Instruction
8.3 Drive To Absolute - DRVA Instruction
B - 127
A
Common Items
B
Built-in
Positioning
Functions
Apx.
Example
Connection
8.3 Drive To Absolute - DRVA Instruction
8.3.1 Instruction Format
1. Instruction format
2. Data setting
*1. Setting range : -32,768 to +32,767 for 16-bit operation
: -999,999 to +999,999 for 32-bit operation
*2. Setting range : 10 to 32,767 Hz for 16-bit operation
For 32-bit operation, however, the setting range is as shown in the following table.
3. Devices
1 : Specify Y000, Y001, or Y002
*3
transistor output from the main unit, or specify Y000, Y001, Y002
*5
, or
Y003
*5
from a high-speed output special adapter
*4
.
*3. Y002 is not available in FX
3G PLC (14-point and 24-point type) and FX3S/FX3GC PLC.
*4. High-speed output special adapters can be connected only to the FX
3U PLC.
*5. To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
Caution:
To use an FX
3U PLC of relay output type or triac output type, be sure to connect a high-speed output
special adapter.
Differential line drive type outputs will be used for the outputs of the high-speed output special adapter.
Operand type Description Data type
Specifies the number of output pulses (absolute address).
*1
BIN16/32-bit
Specifies the output pulse frequency.
*2
Specifies the pulse output number.
Bit
Specifies the rotation direction signal output destination device number.
Pulse output destination Setting range
FX
3U PLC High-speed output special adapter 10 to 200,000(Hz)
FX
3S/FX3G/FX3GC/FX3U/FX3UC PLC Main unit (transistor output) 10 to 100,000(Hz)
Operand
type
Bit device Word device Others
System user Digit designation System user
Spe-
cial unit
Index
Con-
stant
Real
num-
ber
Char-
acter
string
Pointer
XYMTCS
D
.b
KnX KnY KnM KnS T C D R U
\G V Z Modify K H E ""P
4 5 
4 5 
1
2 3
FNC 159
DRVA
DRIVE TO
ABSOLUTE
D
16-bit
instruction
9 steps
DRVA
-
Continuous
execution
type
Instruction
symbol
Execution condition
32-bit
instruction
Instruction
symbol
Execution condition
DDRVA
-
Continuous
execution
type
17 steps
Command
input
FNC159
DRVA
S1 S2 D1 D2
S
1
S
2
D
1
D
2
S
1
S
2
D
1
D
2