PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
12.4 Positioning Using Batch Setting Method
12 Examples of Programs
12.4 Positioning Using Batch Setting Method
Positioning operation will be performed using the absolute positioning method as shown in the following chart:
For details on input/output assignment, refer to Section 12.1
12.4.1 Setting Using GX Works2
This section describes how to set the built-in positioning parameters using GX Works2.
The built-in positioning parameters can be specified only if FX
3UC PLC Ver. 2.20 or later and FX3G/FX3GC/
FX
3U PLC is used.
For details on GX Developer operating procedure, refer to GX Developer Operating Manual.
1 On the project view displayed, double-click on "Parameter" and then "PLC
Parameter".
If the project view is not displayed on the screen, click on "View" in the menu bar, and then click on "Docking
Window", and then click "Navigation".
2 Click on the «Memory Capacity» tab, and then check the "Positioning
Instruction Settings" check box.
9,000 steps are needed to set the built-in positioning data. If there is not enough capacity for programming,
set the "Memory Capacity" to 16,000 steps or
more.
100
Origin
Output pulse frequency:
100,000 Hz
Acceleration/deceleration time:
100 ms
500,000
Check the box.