M800VS/M80V Series Connection and Setup Manual
13 Connection of Machine Operation Panel
13.2 Connecting with Power Supply
321
IB-1501613-A
13.2 Connecting with Power Supply
Connect 24 VDC power supply (general-purpose stabilized power supply) to the main panel of the machine operation panel.
[Related items]
Cable drawing: "15.2.12 J070/J071 Cable"
Connector pin assignment: "4.14.1 Main Panels A/B (FCU8-KB921/FCU8-KB922/FCU8-KB925, FCU8-KB923/FCU8-KB924/
FCU8-KB926)" (DCIN connector)
When sharing the 24 VDC power supply with the control unit, connect a 24 VDC relay cable.
[Related items]
Cable drawing: "15.2.2 G071 Cable"
Connector pin assignment: "4.14.1 Main Panels A/B (FCU8-KB921/FCU8-KB922/FCU8-KB925, FCU8-KB923/FCU8-KB924/
FCU8-KB926)" (DCOUT connector)
FCU8-KB921/KB922/KB923/KB924/KB925/KB926
FCU8-KB921/KB922/KB923/KB924/KB925/KB926
DCIN
J070/J071
1 2 3
Y
0V
FG
24VDC(+)
Stabilized power supply
G071
DCOUT
DCIN
Y
Y
Control unit