M800VS/M80V Series Connection and Setup Manual
15 Cable
15.2 Cable Relating to NC
350
IB-1501613-A
15.2.18 J224 Cable
Max. cable length: 30m
Application: Analog input/output cable (for operation panel I/O unit)
(1) Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to GND plate of the connector.
(2) When using the jackscrew M2.6-type 10320-56S0-008-F for the shell, do not fasten the screws too tightly otherwise the
connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20 ±0.05 N m)
[AIO]
Connector: 10120-3000PE
Case: 10320-56F0-008
Manufacturer: 3M
Wire material: UL2464 U-TKVVBS AWG24 × 2P
Manufacturer: Tachii Electric Wire
Crimp terminal: R1.25-3.5 x 10
Manufacturer: JST
AIO
AI0
AO
AOG
AI0G
AIO
2
1
11
5
15
7
9
AI0G
AI0
AOG
AO
AI
0V
0V
0V
0V
AO
0V
Note

Table of Contents