EasyManua.ls Logo

Mitsubishi Electric M800VS Series - Environment Conditions [M800 VS]; Installation Environment Conditions

Mitsubishi Electric M800VS Series
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.1 Environment Conditions [M800VS]
22
IB-1501613-A
4.1 Environment Conditions [M800VS]
4.1.1 Installation Environment Conditions
(*1) "Short term" means roughly within one month.
(*2) The current consumption of the display unit is included in that of the control unit.
(1) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000 meters
above sea level.
Refer to the manual of drive unit for details.
(2) When the display unit is mounted on an incline, the inclination angle to place the unit should be 30 degrees or less from
the vertical direction.
Item
Unit name Control unit Display unit
Type FCU8-MU551/MA551
FCU8-DU142-31: (10.4-type)
FCU8-DU182-31: (15-type)
General
specifica-
tions
Ambient
tempera-
ture
During op-
eration
0 °C to 58 °C
During
storage
-20 °C to 60 °C
Ambient
humidity
Long term 10% to 75% RH (with no dew condensation)
Short term 10% to 95% RH (with no dew condensation) (*1)
Vibration resistance
4.9 m/s
2
or less
Shock resistance
29.4 m/s
2
or less
Working atmosphere No corrosive gases, dust or oil mist
Altitude
Operation/Storage: 1000 meters or less above sea level, Transportation: 13000 meters or less
above sea level
Power supply voltage
24 VDC FCU8-DU142-31: 12 VDC/5 VDC/3.3 VDC
FCU8-DU182-31: 12 VDC/5 VDC/3.3 VDC
(Supply from control unit)
Current consumption 24 V, 2.5 A - (*2)
Maximum
heating val-
ue
(W)
16 FCU8-DU142-31: 10
FCU8-DU182-31: 14
Mass (kg)
1.1 FCU8-DU142-31: 1.7
FCU8-DU182-31: 3.9
Outline di-
mensions
W × H
or
W × H × D
(mm)
239.1 × 173.4 × 75 FCU8-DU142-31: 290 × 220
FCU8-DU182-31: 400 × 320
Note

Table of Contents

Related product manuals