EasyManua.ls Logo

Mitsubishi Electric MELDAS MDS-R-V1-40 - Parameter No. During Initial Parameter Error

Mitsubishi Electric MELDAS MDS-R-V1-40
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10. Troubleshooting
10 - 20
10-4-3 Parameter No. during initial parameter error
If an initial parameter error (alarm 37) occurs, the alarm and the parameter No. that may be set
incorrectly will appear on the NC Diagnosis screen as shown below. (For M60S, E60 Series NC.)
If a number larger than the parameter No. is displayed for the servo drive unit, the alarm is occurring for
several related parameters. Refer to the following table, and correctly set the parameters.
Error
parameter No.
Details
Related
parameter
2269
The CNC setting maximum rapid traverse rate value is
incorrect.
The CNC system software may be illegal. Turn the power ON
again.
NC setting rapid
2271
The CNC setting maximum cutting speed setting value is
incorrect.
The CNC system software may be illegal. Turn the power ON
again.
NC setting clamp
2301 The following settings are overflowing.
Electronic gears
Position loop gain
Speed feedback
SV001, SV002
SV003, SV018
SV019, SV020
SV049
2302 Other than the absolute position detection is connected.
However, the absolute position detection parameter is valid.
SV017, SV025
2303 The servo option is not available.
The closed loop or dual feedback control function is set.
SV025, SV017
2304 The servo option is not available. The SHG control function is
set.
SV057, SV058
2305 The servo option is not available. SV027
: Error parameter No.
: Axis name display
S02 Initial parameter error

Table of Contents

Related product manuals