Appendix 1. Cable and Connector Specifications
A1 - 20
Appendix 1-4-2 CM10-AP**S Angle Plug Connector
This section explains how to assemble the wire to CM10 angle plug connector.
(1) Cutting a cable
Cut the cable to the following dimensions:
Cable length
* Cable length after cutting = CM10 - AP**S A + cable length
= A + cable length
(2) Stripping a cable sheath
Strip the cable sheath to the following dimensions:
A
Sheath
Core
wire
Product name A
CM10-AP**S-S-**
CM10-AP**S-M-**
40mm
CM10-AP**S-L-** 55mm
Product name A
CM10-AP**S-S-**
CM10-AP**S-M-**
30mm
CM10-AP**S-L-** 45mm