5. Peripheral Devices
5 - 8
5-5 Noise filter
(1) Selection
Use an EMC noise filter if the noise conducted to the power line must be reduced. Select an EMC
noise filter taking the drive unit's input rated voltage and input rated current into consideration.
(2) Noise filter mounting position
Install the noise filter to the drive unit’s power input as the diagram below indicates.
Drive unit
MDS-R-V1/V2
Noise filter
T
S
R
Breaker
Power
supply
Power
distribution panel
Contactor
(Note) The noise filter must be prepared by the user.
Recommended devices: Densei-lambda MX13 Series
Soshin Electric HF3000C-TM Series
Contact: Densei-lambda Co., Ltd. TEL0120-507039
http://www.densei-lambda.com
Soshin Electric Co., Ltd. TEL03-3775-9112(+81-3-3775-9112)
http://www.soshin.co.jp
(Note) The above devices may be changed at the manufacturer's discretion.