EasyManua.ls Logo

Mitsubishi Electric MELDAS MDS-R-V1-40 - Prevention of Foreign Matter Entry; Panel Installation Hole Machining Drawings (Panel Cut Drawings)

Mitsubishi Electric MELDAS MDS-R-V1-40
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Installation
6 - 10
6-2-3 Prevention of foreign matter entry
Treat the cabinet with the following items.
Make sure that the cable inlet is dust and oil proof by
using packing, etc.
Make sure that the external air does not enter inside
through heat radiating holes, etc.
Close all clearances of the cabinet.
Securely install door packing.
If there is a rear cover, always apply packing.
Oil will tend to accumulate on the top. Take special
measures such as oil-proofing packing so that oil does
not enter the cabinet from the screw holes.
After installing each unit, avoid machining in the
periphery. If cutting chips, etc., stick onto the
electronic parts, trouble may occur.
When using the unit in an area with toxic gases or high
levels of dust, protect the unit with air purging (system
to blow clean air so that the panel's inner pressure is
higher than the outer pressure).
6-2-4 Panel installation hole machining drawings (Panel cut drawings)
Prepare a square hole to match the unit width.
342
360
82
Unit width: 90mm
2-M5 screw
hole
Square
hole
(Note 1)
Unit [mm]
342
360
52
Unit width: 60mm
2-M5 screw
hole
Square
hole
(Note 1)
Unit [mm]
10
10
(8)
(8)
(Note 1) Attach packing around the square hole to provide a seal.

Table of Contents

Related product manuals