EasyManua.ls Logo

Mitsubishi Electric MELDAS MDS-R-V2-2020 - Selection of Contactor

Mitsubishi Electric MELDAS MDS-R-V2-2020
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Peripheral Devices
5 - 5
5-2-2 Selection of contactor
Select the contactor as in the expression below.
Unit type
MDS-R-
V1-20 V1-40 V1-60 V1-80
Recommended
contactor
(Mitsubishi Electric
Corp.: option part)
S-N12
-AC200V
S-N18
-AC200V
S-N20
-AC200V
S-N25
-AC200V
Free-air thermal
current of the
recommended
contactor
20A 25A 32A 50A
Unit type
MDS-R-
V2-2020 V2-4020 V2-4040 V2-6040 V2-6060 V2-8040 V2-8060 V2-8080
Recommended
contactor
(Mitsubishi Electric
Corp.: option part)
S-N18
-AC200V
S-N20
-AC200V
S-N20
-AC200V
S-N20
-AC200V
S-N25
-AC200V
S-N25
-AC200V
S-N25
-AC200V
S-N25
-AC200V
Free-air thermal
current of the
recommended
contactor
25A 32A 32A 32A 50A 50A 50A 50A
Option part: A breaker is not prepared as an NC unit accessory, so purchase the part from your dealer, etc.
POINT
Select a contactor whose excitation coil does not operate at 15mA or less.