7 POSITIONING MODULE REPLACEMENT
7 - 14
Item of AD75P-S3
Buffer memory address
AD75P-S3 QD75PN/QD75DN
Common for axis 1, 2, 3 Common for axis 1, 2, 3, 4
In test mode flag
450 1200
Module name
451 -
OS type
452 453
454 455
-
OS version
456
457
-
Clock data (hour: minute)
460 -
Clock data (second: 100 ms)
461 -
(Pointer number)
Start history
(0) to (15)
Start axis
462 to 537 1212 to 1287
(QD75PN/QD75DN: Start information)
Operation type
463 to 538 1213 to 1288
(QD75PN/QD75DN: Start No.)
Start Hour: minute
464 to 539 1214 to 1289
(QD75PN/QD75DN: Start Hour)
Start Second: 100 ms
465 to 540 1215 to 1290
(QD75PN/QD75DN: Start Minute: second)
Error judgment
466 to 541 1216 to 1291
Start history pointer
542 1292
(Pointer number)
Start history during errors
(0) to (15) -
Start axis
543 to 618 -
Operation type
544 to 619 -
Start Hour: minute
545 to 620 -
Start Second: 100 ms
546 to 621 -
Error judgment
547 to 622 -
Start history storage during error
623 -
(Pointer number)
Error history
(0) to (15)
Axis in which the error occurred
624 to 684 1293 to 1353
Axis error No.
625 to 685 1294 to 1354
Axis error occurrence Hour: minute
626 to 686 1295 to 1355
(QD75PN/QD75DN: Axis error occurrence
(Hour))
Axis error occurrence Second: 100 ms
627 to 687 1296 to 1356
(QD75PN/QD75DN: Axis error occurrence
(Minutes: second))
Error history pointer
688 1357
Md.3
Md.4
Md.9
Md.5
Md.6
Md.11
Md.12