1 - 14
INTRODUCTION
1
1.1.3 Replacement selection points
To replace any one stations in the existing MELSECNET(II) with the QCPU or to add the QCPU in the
system, replace the network used with the MELSECNET/10 simultaneously.
(1) Replacing the existing A/AnS/QnA/QnASCPU with the QCPU
This section describes the methods for replacing the network used with the MELSECNET/10
simultaneously and replacing any one stations in the existing MELSECNET(II) with the QCPU.
: No restrictions, : Some restrictions, : Many restrictions
*1 Twisted pair cables can be used by replacing the remote I/O station with a normal station and configuring a PLC to PLC
network.
Existing network configuration Replaced network configuration
Item Advantage Outline Reference
Cost
Cable
laying
Optical
cable
Laying change is not required since the existing network
cable can be used without change.
Due to restrictions on station-to-station distance in some
cable types, check the cable type if the distance is long.
Section 2.2.1
(1)
Coaxial
loop
Change from coaxial loop to coaxial bus is required.
One side of the existing coaxial cable can be utilized.
Due to restrictions on overall cable distance, if the distance
is long, repeater module is required.
Section 2.2.1
(2)
Twisted
pair
Since the twisted pair cables can be used for the
MELSECNET/H only, all stations must be replaced with
QCPU.
When replacing the stations with QCPU step-by-step or
replacing with the remote I/O network, change the twisted
pair cables to coaxial bus cables. (The twisted pair cables
cannot be used for the remote I/O network.)
*1
Section 2.2.1
(3)
Network module
All the existing stations are required to be replaced with the
MELSECNET/10 modules.
-
Modification
on software
Only first half set
in second tier
system
Setting made to the existing network parameter can be
utilized without change.
Section 2.5.1
(1)
Latter half set in
second tier system
Station-specific parameter setting is required.
If the AnN, AnA, or AnSCPU (excluding AnUS(H)CPU)
exists, newly set network parameters and modify the
program.
Section 2.5.1
(1)
Three-tier system
Since the second tier and the third tier is separate network,
reviewing the network parameter and program is required
Section 2.5.3,
Section 2.5.4
Extensibility
By simultaneous replacement to the MELSECNET/10,
replacing arbitrary station with the QCPU is possible.
If modification on software is required, modifying it at
replacement of the first module allows omitting modification
to the second module or later.
-
A6
A5A3
A2
A1
MELSECNET(II)
A4
A6
Q5A3
A2
A1
MELSECNET/10
A4
Replaced QCPU