7 Buffer Memory
7.2 Buffer Memory List
53
FX3U-1PG User's Manual
1
Introduction
2
Specification
3
System
Configuration
4
Installation
5
Wiring
6
Before Starting
Positioning
Operation
7
Buffer Memory
8
Manual Control
9
Positioning
Control
10
Program
Example
R/W : Read or Write
R : Read only
- - #31 Not used - - - -
Positioning parameter
-#32
Positioning parameter
selection
Positioning parameter type is selected. H0000 R/W
Subsection
7.3.12
#34 #33 Pulse rate
Number of pulses to rotate the motors once.
1 to 2,147,483,647 PLS/REV
K2,000 R/W
Subsection
7.3.13
#36 #35 Feed rate
Travel distance per revolution of the motor.
1 to 2,147,483,647 (user unit)
K1,000 R/W
Subsection
7.3.14
- #37 Operation parameter
Setting of basic conditions such as the unit
system
H0000 R/W
Subsection
7.3.15
#39 #38 Maximum speed
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
K100,000 R/W
Subsection
7.3.16
#41 #40 Bias speed
0 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
K0 R/W
Subsection
7.3.17
#43 #42 JOG speed
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
K10,000 R/W
Subsection
7.3.18
#45 #44
Zero return speed
(high speed)
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
K50,000 R/W
Subsection
7.3.19
#47 #46
Zero return speed
(creep)
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
K1,000 R/W
Subsection
7.3.20
-#48
Number of zero-point
signal for zero return
Number of zero-point signals for zero return
0 to 32,767
K10 R/W
Subsection
7.3.21
#50 #49 Zero-point address
Address at the zero return completion
-2,147,483,648 to 2,147,483,647 (user unit)
Set the value within -2,147,483,648 to
2,147,483,647 PLS when converted to pulse data.
K0 R/W
Subsection
7.3.22
- #51 Acceleration time
Time from the bias speed to the maximum speed
Trapezoidal acceleration/deceleration:
1 to 32,767 ms
Approximate S-shaped acceleration/deceleration:
1 to 5,000 ms
However, the acceleration and deceleration
times are the same for approximate
S-shaped
acceleration/deceleration.
K100 R/W
Subsection
7.3.23
-#52Deceleration time
Time from the maximum speed to the bias speed
Trapezoidal acceleration/deceleration:
1 to 32,767ms
Approximate S-shaped acceleration/deceleration:
Same as the acceleration time
K100 R/W
Subsection
7.3.24
Control data
#54 #53
Target address change
value
-2,147,483,648 to 2,147,483,647 (user unit)
Set the value within -2,147,483,648 to
2,147,483,647 PLS when converted to pulse data.
K0 R/W
Subsection
7.4.7
#56 #55
Operation speed
change value
1 to 2,147,483,647 (user unit)
Set the value within 1 to 200,000 Hz when
converted to pulse data.
*2
K0 R/W
Subsection
7.4.8
- #57 Operation command ΙΙ Interrupt input via the PLC (BFM) H0000 R/W
Subsection
7.4.9
Monitor data
#59 #58
Current address
(pulse converted value)
-2,147,483,648 to 2,147,483,647 PLS K0 R/W
Subsection
7.5.5
#61 #60
Current value of
operation speed
0 to 2,147,483,647 (user unit) K0 R
Subsection
7.5.6
- #62 Version information The version of FX3U-1PG is stored. - R
Subsection
7.5.7
BFM No.
Item Content, Setting range Default R/W Reference
High order
16bit
Low order
16bit