7 Applied Instructions
7.15 Real Time Clock Control
561
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
1
Outline
2
Instruction List
3
Configuration of
Instruction
4
How to Read
Explanation of
Instructions
5
Basic Instruction
6
Step Ladder
Instructions
7
Applied
Instructions
8
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
Function and operation explanation
1. 16-bit operation (TZCP, TZCPP)
The comparison time (hour, minute, second) of higher and lower points and the time data (hour, minute,
second) of the device specified by are compared, and the device specified by is turned ON or OFF
depending on the magnitude of difference.
Cautions
1) Number of devices occupied
Three devices are occupied each in , , and .
Be careful not to overlap with the devices used in machine control.
2) When using the time (hour, minute, second) of the clock data of the real time clock built in the PLC, first
read out the value of the special data register by using TRD, TRDP, and specify the word device in each
operand.
3) Applicable devices are limited.
S1: FX
3U, FX3UC PLCs only are applicable, index (V, Z) decoration is disabled.
S2: FX
3U, FX3UC, FX3G PLCs only are applicable.
S3: FX
3U, FX3UC PLCs only are applicable.
>
>
≤≤
Command input
Magnitude comparison function
of specified time at two points
and time data
+1 (minute)
(hour)
+2 (second)
+1 (minute)
(hour)
+2 (second)
+1 (minute)
(hour)
+2 (second)
+1 (minute)
(hour)
+2 (second)
+1 (minute)
(hour)
+2 (second)
+1 (minute)
(hour)
+2 (second)
+1 (minute)
(hour)
+2 (second)
and then turned ON
and then turned ON
and then turned ON
+1
+2
TZCP
EN
s1
s2
ENO
d
s
Comparison lower limit time (hour, minute, second) "hour"
Comparison upper limit time (hour, minute, second) "hour"
Time data (hour, minute, second) "hour"
Device to be turned ON or OFF
depending on the comparison result.
s2
s2
s2
s2
s2
s2s
s
s
s
s
s
d
d
d
s
s
s
s1
s1
s1
s1
s1
s1
d d d
If TZCP is not executed when command contact is changed from ON to OFF, , +1, +2
are holding the state before the command contact is turned OFF.