7 Applied Instructions
7.24 External Device Communication (Inverter
743
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
1
Outline
2
Instruction List
3
Configuration of
Instruction
4
How to Read
Explanation of
Instructions
5
Basic Instruction
6
Step Ladder
Instructions
7
Applied
Instructions
8
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
Function and operation explanation
For detailed explanation of the instruction, refer to the Data Communication Edition manual.
1. 16-bit operation (IVBWR)
A data table (parameter numbers and set values) specified in and is written to an inverter
*1
connected to a communication port n whose station number is in the device specified by all at once.
*1. Mitsubishi Electric's FREQROL - F700, A700, E700, D700, V500, F500, A500, E500 and S500 series
general purpose inverters
*2. The table below shows the data table format.
: Number of parameters to be written
: Head device number of data table
2. Related devices
For the instruction execution complete flag use method, refer to Section 1.3.4.
*1. Cleared when the PLC mode switches from STOP to RUN.
*2. Initial value: -1
Cautions
For other cautions, refer to the Data Communication Edition manual.
1) It is not permitted to use the RS and RS2 instructions and an inverter communication instruction (IVCK,
IVDR, IVRD, IVWR and IVBWR) for the same port.
2) Two or more inverter communication instructions (IVCK, IVDR, IVRD, IVWR and IVBWR) can be driven
for the same port at the same time.
Device Parameter numbers to be written and set values
1st parameter
Parameter number
+1
Set value
+2
2nd parameter
Parameter number
+3
Set value
...
...
...
+2 -4
- 1"th parameter
Parameter number
+2 -3
Set value
+2 -2
th parameter
Parameter number
+2 -1
Set value
Number
Description
Number
Description
ch1 ch2 ch1 ch2
M8029 Instruction execution complete D8063 D8438 Error code of serial communication error
M8063 M8438 Serial communication error D8150 D8155 Response wait time in inverter communication
M8151 M8156
Inverter communicating*
1
D8151 D8156
Step number in inverter communication*
2
M8152 M8157
Inverter communication error*
1
D8152 D8157
Error code of inverter communication error*
1
M8153 M8158
Inverter communication error latch*
1
D8153 D8158
Latch of inverter communication error occurrence
step*
2
M8154 M8159
IVBWR instruction error*
1
D8154 D8159
IVBWR instruction error parameter number*
2
IVBWR
EN ENO
s1
s2
s3
n
Inverter station number
Command
input
Number of parameters in an inverter to be written at one time.
Head address of a parameter table to be written to an inverter
Channel to be used