Learning to Use the FX Family for Positioning Control FX2N-10GM and FX2N-20GM positioning
4 - 60
MITSUBISHI ELECTRIC
Double click the current position display in the
Monitoring
window to set the start point.
The next step is to switch the FX
2N
-20GM to "AUTO" mode by moving the switch on the unit to
"AUTO".
Finally, on the
Monitoring Window
screen, click on either the
X START
or
Y START
buttons.
The positioning operation will be performed and the plot result should look identical to the one
shown in the following picture.
To run the program again, set a new start position (or let it start from where it is), clean the plot
area, and press the
X START
or
Y START
button again.
If the plot does not look like the one above, check the flow chart program against the program
listed in
section 4.5.2 (Creating a Flow Chart).
Fig. 4-43: Monitoring
Window
453040da.eps
Fig. 4-44:
Resulting path of travel and flow chart
453030da.eps
After editing the current address to X: 50 and Y: 125, click on
the
Write to FX-GM
button for each axis.
As the address information is changed, red lines will appear
on the plotter. This shows the current position.
To clear these red lines before positioning, double click on
the plotting area, and then click on the
Clear
button.