10
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
PLC User's Manual - Analog Control Edition
Table of Contents
5.4.17 BFM#50: Setting of output corrective function by load resistance
(only in voltage output mode)/BFM#51 to #54: Load resistance values...................................E-33
5.4.18 BFM#60: Status automatic transfer function setting.................................................................E-34
5.4.19 BFM#61: Error status data automatic transfer-to data register specification............................E-35
5.4.20 BFM#62: Upper/lower limit function status data automatic transfer-to data register
specification.............................................................................................................................E-36
5.4.21 BFM#63: Specification of data register for automatic transfer at disconnection detection .......E-37
5.4.22 BFM#80 to #3098: Table output function .................................................................................E-37
6. Table Output Function E-38
6.1 Outline of Table Output Function ...............................................................................................E-38
6.2 Preparation of data table............................................................................................................E-39
6.3 Procedures for transferring data table to buffer memory ...........................................................E-44
6.4 Procedures for executing table output function..........................................................................E-48
6.5 Details of table output error........................................................................................................E-50
6.6 Examples uses of table output function .....................................................................................E-52
7. Changing Output Characteristics E-53
7.1 Procedure for Changing Output Characteristics ........................................................................E-53
8. Examples of Practical Programs E-56
8.1 Example of Program for Analog Output Operation (Regular Operation)....................................E-56
8.2 Example of Program using Useful Functions .............................................................................E-57
8.3 Example of Program for Table Output Operation (Pattern Output Operation)...........................E-60
8.4 Program to Initialize FX
3U-4DA (Factory Default)......................................................................E-63
9. Troubleshooting E-64
9.1 PLC Version Number Check ......................................................................................................E-64
9.2 Wiring Check..............................................................................................................................E-64
9.3 Program Check ..........................................................................................................................E-64
9.4 Error Status Check.....................................................................................................................E-65
9.5 FX
3U-4DA Initialization and Test Program.................................................................................E-66