2 SERVO AMPLIFIER SETTING
2.3 Ethernet Parameter Settings
14
2
2.3
Ethernet Parameter Settings
Connect the servo amplifiers and the personal computer with the Ethernet cables, and set the parameters.
This manual describes the parameter setting method using MR Configurator2.
1.
When the power of servo amplifiers is off, set the fourth octet of IP addresses of servo amplifiers using the rotary
switches.
2.
Power on the servo amplifiers.
3.
Start MR Configurator2, and select [Project] [New].
4.
Click [Switch to Multi-axis Project].
[Station number 1]
Turn the rotary switches to set
as shown on the left side.
(01h)
•SW116: 0
•SW21: 1
[Station number 2]
Turn the rotary switches to set
as shown on the left side.
(02h)
•SW116: 0
•SW21: 2
MR-JET-G
(Station number 1)
MR-JET-G
(Station number 2)
Ethernet
MR Configurator2MR Configurator2