1 Outline
1.2 Substitute Models
17
1
Selection and Replacement of the Models
The CPU modules and extension modules of FX3G/FX3U/FX3UC can be replaced by selecting models from the successor
models FX5S/FX5UJ/FX5U/FX5UC that match the system.
Select models according to the following selection table.
Selection table
This selection table describes main performance specifications of the FX5.
For performance specifications, functions and external dimensions not described in the following table, refer to the relevant
part in this manual or the user's manual of each module.
: Supported, : Not supported
Item Required
functions
FX3G FX3U FX3UC FX5S
*1
FX5UJ
*2
FX5U
*3
FX5UC
*3
Remarks
Power supply AC power supply 
DC power supply 
Main unit output
type
Relay 
Transistor 
Program
memory capacity
48000 steps or less  Convert the project in GX Works3,
and then check the number of
program steps.
More than 48000
steps

Number of input/
output points
(Including
remote I/O)
256 points or less  FX5S/FX5UJ: Using CC-Link IE
Field Basic remote I/O enables a
system configuration with 256 or
more inputs and outputs. For
details, refer to the CC-Link IE
Field Network Basic Reference
Manual.
More than 256
points

Clock function  FX5S/FX5UJ: The clock data is
maintained (for 15 days) with the
internal, large-capacity capacitor
of the CPU module. If the voltage
of the large-capacity capacitor
drops, the clock data will not be
maintained correctly.
FX5U/FX5UC: The clock data is
maintained (for 10 days) with the
internal, large-capacity capacitor
of the CPU module. When the
optional battery is in use,
operation is continued with the
battery.
The FX5S, FX5UJ, FX5U, and
FX5UC support a time setting
function (an SNTP client). Check
whether this function can be
substituted. For details, refer to
MELSEC iQ-F FX5 User's
Manual (Ethernet Communication).
Extension
module
8 units or less  Extension modules cannot be
connected to the FX5S.
More than 8 units 
Serial
communication
channel
2 channels or less  FX5S/FX5UJ: These products have
a built-in Ethernet port and USB
port. Check whether the required
serial communication function can
be replaced with the built-in
Ethernet or USB interface of the
FX5S/FX5UJ.
More than 2
channels

Analog
expansion
adapter
2 units or less  FX5UJ: The intelligent function
module for analog control can be
used. If the number of analog
expansion adapters is insufficient,
check whether the situation can be
handled with an FX5 intelligent
function module.
More than 2 units 