94
APPX
Appendix 1 Instruction Replacement List
*1 For GX Works3 version 1.032J and later, the instructions will be replaced when a timer device is assigned to the global label.
*2 For GX Works3 version 1.038Q and earlier, the instructions will be replaced with OUT SM4095.
When inline ST is used with the ladder program, instructions and devices can be replaced like ST programs. However,
readout of the program may fail depending on the following conditions.
• If a syntax error exists
• If the program exceeds 2048 characters
If there is an instruction that is not supported by the MELSEC iQ-F Series in the program created using GX Works2, the
instruction will be changed to the instruction using SM4095/SD4095.
WR3AP OUT SM4095 Correct the program to use TOP
instruction.
LOADR ERREAD
*2
SAVER OUT SM4095 Correct the program to use
ERWRITE instruction.
INITR OUT SM4095 Correct the program to use FMOV
instruction. Correct the program to
collectively initialize (clear to 0) the
required number of points of the file
register (R).
INITRP OUT SM4095 Correct the program to use FMOVP
instruction. Correct the program to
collectively initialize (clear to 0) the
required number of points of the file
register (R).
LOGR OUT SM4095 Use the data logging function.
Save the collected data to the SD
memory card as a CSV file or binary
file.
*The data cannot be stored in the file
register (R) or the extension file
register (ER) in the SD memory card.
LOGRP OUT SM4095
RWER ERWRITE
*2
RWERP ERWRITE
*2
INITER ERINIT
*2
INITERP ERINIT
*2
FLCRT OUT SM4095 These instructions are not supported
by MELSEC iQ-F. Therefore, It will be
replaced to OUT SM4095.
FLDEL OUT SM4095
FLWR OUT SM4095
FLRD OUT SM4095
FLCMD OUT SM4095
FLSTRD OUT SM4095
ASC OUT SM4095
FX3 Series MELSEC iQ-F Remarks