Appendix 6 Processing Time
ndl (RXl/8) + (RWrl 2) + 8
RXl: Number of points of "RX Setting" of main modules of the device station
*2
to be used as the maximum number of link points
RWrl: Number of points of "RWr Setting" of main modules of the device station
*2
to be used as the maximum number of link points
E E: (Sn-1)830+39102
Round up values of E that are less than 1s.
n7 When "CC-Link IE TSN Class Setting" is set to "Mixture of CC-Link IE TSN Class B/A or CC-Link IE TSN Class A Only", and "TSN
HUB Setting" is set to "Not to Use TSN HUB": 4
Other than the above: 0
en1
en1
i
= ((endm
i
+ en2
i
16)/1488)
*3
-k
i
However, when endm
i
is 0, en1
i
is 0.
When mf
i
>16, k
i
=1, and when mf
i
16, k
i
=0.
mf
i
=1488-mod
mod: Remainder of {((mRy
i
+ (mRy
i
/1472)
*3
16) + (mRWw
i
+ (mRWw
i
/1472)
*3
16))/1488}
However, the value is 0 when the calculation result of mf
i
is 1488.
i: Station number
mRy
i
: Number of points of "RY Setting" of main modules with station No.i/8
mRWw
i
: Number of points of "RWw Setting" of main modules with station No.i2
en2
en2
i
= eRyn
i
+ eRWwn
i
+ ((endm
i
+ (eRyn
i
+ eRWwn
i
)16)/1488)
*3
-1
However, when endm
i
is 0, en2
i
is 0.
i: Station number
eRyn
i
: 0 (fixed)
eRWwn
i
: Total number of extension modules with station No.i whose number of points of "RWw Setting" is more than 0
endm
endm
i
= eRyAll
i
/8 + eRWwAll
i
2
i: Station number
eRyAll
i
: 0 (fixed)
eRWwAll
i
: Total number of points of "RWw Setting" of extension modules with station No.i
en3
en3
i
= ((ends
i
+ en4
i
20)/1488)
*3
-k
i
However, when ends
i
is 0, en3
i
is 0.
When sf
i
>20, k
i
=1, and when sf
i
20, k
i
=0.
sf
i
=1488-mod
mod: Remainder of {((mRx
i
+ (mRx
i
/1468)
*3
20) + (mRWr
i
+ (mRWr
i
/1468)
*3
20))/1488}
However, the value is 0 when the calculation result of sf
i
is 1488.
i: Station number
mRx
i
: Number of points of "RX Setting" of main modules with station No.i/8
mRWr
i
: Number of points of "RWr Setting" of main modules with station No.i2
en4
en4
i
= eRxn
i
+ eRWrn
i
+ ((ends
i
+ (eRxn
i
+ eRWrn
i
)20)/1488)
*3
-1
However, when ends
i
is 0, en4
i
is 0.
i: Station number
eRxn
i
: 0 (fixed)
eRWrn
i
: Number of extension modules with station No.i whose number of points of "RWr Setting" is more than 0
ends
ends
i
= eRxAll
i
/8 + eRWrAll
i
2
i: Station number
eRxAll
i
: 0 (fixed)
eRWrAll
i
: Total number of points of "RWr Setting" of extension modules with station No.i
Name of variable Description
en1
i
6
i = 1
60
en2
i
6
i = 1
60
endm
i
6
i = 1
60
en3
i
6
i = 1
60
en4
i
6
i = 1
60
ends
i
6
i = 1
60