968
APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
*1 This item is displayed when "Device" is specified as "Logging target" in the "Logging type" window.
*2 This item is displayed when "Label" is specified as "Logging target" in the "Logging type" window.
*3 The default of "Device specification" or "Label specification" when "Condition specification" is selected is shown.
Condition
specification
Device specification
*1
Specify this item for collecting data at the END
processing where the specified device condition
has been satisfied. If both the step No. and
device are specified as conditions, the data is
collected when the both conditions are satisfied.
Page 175 Device/label
specification
Checked
*3
Label specification
*2
Specify this item for collecting data at the END
processing where the specified label condition
has been satisfied. If both the step No. and label
are specified as conditions, the data is collected
when the both conditions are satisfied.
Not checked
*3
Step No. specification Specify this item for collecting data when the
condition is satisfied immediately before
execution of the specified step No.
Page 177 Step No. specification
Item Description Setting range Default