13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
13.1 User Frame
253
13
Delete registered data (command: 1610)
Delete the registered user frame.
Message format
The following shows the message format of the request data and response data of the command.
■Request data
■Response data
There is no response data for this command.
Data specified by request data
■Command
*1 For C24, an additional code is added. (Page 35 Additional code (10H))
■Subcommand
■Frame No.
Specify the number of user frame to be deleted. (Page 247 Frame No.)
When the frame No. whose user frame is not registered is specified, an error occurs and an abnormal
response is returned.
■Number of registration data byte, number of frame byte
Specify '0'.
ASCII code Binary code
*1
ASCII code Binary code
Type Setting value Registration destination
User frame 3E8H to 4AFH Flash ROM of C24
8001H to 801FH Buffer memory of C24 (addresses 1B00H to 1FF6H)
ASCII code Binary code
Command Subcommand Frame No.
Number of
registration
data byte
Number of
frame byte