274
13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
13.5 Programmable controller CPU monitoring function
Data communication in ASCII code
(Request data)
(Response data)
In the figure (1) and (2), set the value of "ASCII Code" in the table of "Device data" of each response data.
The order of device data differ depending on the setting of "Word/byte units designation" in Engineering tool.
01
30
H
31
H
001
30
H
30
H
31
H
E01
45
H
30
H
31
H
000
30
H
30
H
30
H
2
32
H
010
30
H
31
H
30
H
1
31
H
063
30
H
36
H
33
H
0
30
H
000
30
H
30
H
30
H
0
30
H
D*0
44
H
2A
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
4
34
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
W* 0
57
H
2A
H
30
H
0
30
H
010
30
H
31
H
30
H
0
30
H
000
30
H
30
H
30
H
8
38
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
M* 0
4D
H
2A
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
2
32
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
010
30
H
31
H
30
H
0
30
H
000
30
H
30
H
30
H
000
30
H
30
H
30
H
1
31
H
0
30
H
0
30
H
0
30
H
0
30
H
1
31
H
5
35
H
0
30
H
0
30
H
0
30
H
Subcommand
Cycle
time unit
Transmission
method
Number of
registered
word blocks
CPU error
monitoring
Number of
registered
bit blocks
Cycle time
Monitoring start device
Number of registered
points
Monitoring
condition
Monitoring
condition value
Monitoring start device
Number of
registered points
Monitoring
condition
Monitoring
condition value
Monitoring start device
Number of
registered points
Monitoring
condition
Monitoring
condition value
Word device registration (first point)
Word device registration (second point)
Bit device registration (first point)
D0 to D3
W100 to D107
M0 to M31
CPU error monitoring registration (Fixed value)
Programmable
controller CPU
monitoring function
D*0
44H 2AH 30H
0
30H
000
30H 30H 30H
0
30H
000
30H 30H 30H
4
34H
M* 0
4DH 2AH 30H
0
30H
000
30H 30H 30H
0
30H
000
30H 30H 30H
2
32H
010
30H 31H 30H
0
30H
000
30H 30H 30H
0
30H
0
30H
0
30H
0
30H
1
31H
1
31H
0
30H
0
30H
0
30H
010
30H 31H 30H
2
32H
010
30H 31H 30H
1
31H
2
10
32H
31H 30H
2
32H
(1)
(2)
Programmable
controller CPU
monitoring function
Number of
registered
word blocks
Number of
registered
bit blocks
CPU error
monitoring
Fixed value
Word device information
Monitoring start device
Number of
registered points
Device data
(first point) (second point)
Bit device information
Number of
registered points
Device data
Monitoring start device
CPU status information
Device data