13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
13.5 Programmable controller CPU monitoring function
277
13
Data communication in ASCII code
(Request data)
(Response data)
In the figure (1) and (2), set the value of "ASCII Code" in the table of "Device data" of each response data.
The order of device data differ depending on the setting of "Word/byte units designation" in Engineering tool.
01
30
H
31
H
001
30
H
30
H
31
H
E02
45
H
30
H
32
H
000
30
H
30
H
30
H
2
32
H
010
30
H
31
H
30
H
1
31
H
063
30
H
36
H
33
H
0
30
H
000
30
H
30
H
30
H
0
30
H
D*0
44
H
2A
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
4
34
H
000
30
H
30
H
30
H
1
31
H
006
30
H
30
H
36
H
3
33
H
W* 0
57
H
2A
H
30
H
0
30
H
010
30
H
31
H
30
H
0
30
H
000
30
H
30
H
30
H
8
38
H
000
30
H
30
H
30
H
2
32
H
000
30
H
30
H
30
H
0
30
H
M* 0
4D
H
2A
H
30
H
0
30
H
000
30
H
30
H
30
H
0
30
H
000
30
H
30
H
30
H
2
32
H
000
30
H
30
H
30
H
2
32
H
000
30
H
30
H
30
H
0
30
H
010
30
H
31
H
30
H
0
30
H
000
30
H
30
H
30
H
000
30
H
30
H
30
H
1
31
H
0
30
H
0
30
H
0
30
H
0
30
H
1
31
H
5
35
H
0
30
H
0
30
H
0
30
H
Subcommand
Cycle
time unit
Transmission
method
Number
of registered
word blocks
CPU error
monitoring
Number
of registered
bit blocks
Cycle time
Monitoring start device
Number of
registered points
Monitoring
condition
Monitoring
condition value
Monitoring start device
Number of
registered points
Monitoring
condition
Monitoring
condition value
Monitoring start device
Number of
registered points
Monitoring
condition
Monitoring
condition value
Word device registration (first point)
Word device registration (second point)
Bit device registration (first point)
D0 to D3 D0=99
W100 to D107 W100≠0
M0 to M31 M0≠OFF
CPU error monitoring registration (Fixed value)
Programmable
controller CPU
monitoring function
020
30H 32H 30H
1
31H
000
30H 30H 30H
0
30H
2
10
32H
31H 30H
2
32H
D*0
44H 2AH 30H
0
30H
000
30H 30H 30H
0
30H
000
30H 30H 30H
4
34H
2
32H
020
30H 32H 30H
0
30H
010
30H 31H 30H
30H
2
10
32H
31H 30H
2
32H
M* 0
4DH 2AH 30H
0
30H
000
30H 30H 30H
0
30H
000
30H 30H 30H
(2)
(1)
1
32H
020
30H 32H 30H
0
30H
000
30H 30H 30H
1
31H
2
10
32H 31H 30H
2
32H
010
30H 31H 30H
0
30H
000
30H 30H 30H
0
30H
000
30H 30H 30H
1
32H
000
30H 30H 30H
When the condition (D0 = 99) of word device registration (first point) is established
Number
of registered
word blocks
Number
of registered
bit blocks
CPU error
monitoring
Programmable
controller CPU
monitoring function
Number
of registered
word blocks
Number
of registered
bit blocks
CPU error
monitoring
Programmable
controller CPU
monitoring function
Number
of registered
word blocks
Number
of registered
bit blocks
CPU error
monitoring
Programmable
controller CPU
monitoring function
Fixed value
Monitoring start device
Number of
registered points
Number of
registered points
Device data
Word device information
When the condition (M0 ≠ OFF) of bit device registration (first point) is established
Fixed value
Monitoring start device
Device data
Bit device information
When the condition of CPU error monitoring is established(Module warning being generated)
Fixed value
Fixed value Device data
CPU status information