18 COMMUNICATING USING 1E FRAMES
18.4 Read and Write Device Memory
Communication example
Write the bit devices in the CPU module with E71 mounted under the following conditions.
Head device: M50
Number of device points: 12 points
Data communication in ASCII code
(Request data)
Data communication in binary code
(Request data)
34
H
44
H
32
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
33
H
32
H
30
H
43
H
30
H
30
H
31
H
31
H
30
H
31
H
4420 000000 32
0300 11 01
(M50)
(M61)
Head device
Number of device points Data for the number of specified device points
to
32
H
00
H
00
H
00
H
20
H
4D
H
0C
H
00
H
01
H
11
H
01
H
00
H
00
H
01
H
011101000001
Number of device points
Head device
Data for the number of specified device points
(M50) to (M61)