15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
1461
15
Reading data from the programmable controller on another
station (with notification)
JP.SREAD, GP.SREAD
These instructions read data from a device in the programmable controller of another station. (in units of words)
After the data reading is completed by the SREAD instruction, the device of another station is turned on. The other station can
recognize that data has been read by the SREAD instruction.
Execution condition
Setting data
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
*2 For the specifications of the string data to be specified, refer to the following.
Page 1452 Specifications of character string data specified by link dedicated instructions
Ladder ST
ENO:=JP_SREAD(EN,J,s1,s2,d1,d2,d3);
ENO:=GP_SREAD(EN,U,s1,s2,d1,d2,d3);
FBD/LD
Instruction Execution condition
JP.SREAD
GP.SREAD
Operand Description Range Data type Data type (label)
(J/U) JP.SREAD (J): Own station network number 1 to 239 16-bit unsigned binary ANY16
GP.SREAD (U): Start I/O number (first three digits in four-
digit hexadecimal representation) of own station
or own node
00H to FEH 16-bit unsigned binary ANY16
(s1) Own station start device where control data is
stored
Refer to the control data. Device name ANY16
*1
(s2) Target station start device where the data to be
read is stored
String
*2
ANYSTRING_SINGLE
*2
(d1) Own station start device for storing the read data Device name ANY16
*1
(d2) Device of the own station, which turns on for one
scan upon completion of the instruction.
When the instruction completes with an error,
(d2)+1 also turns on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
(d3) Device of the target station, which turns on for
one scan upon completion of the instruction.
(The target station can recognize that data has
been read from another station.)
String
*2
ANYSTRING_SINGLE
*2
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(s1) (s2) (d1) (d2) (d3)(J/U)
EN ENO
d1
d2
J/U
s1
s2
d3