15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
1493
15
■Applicable devices
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
■Control data
Operand Bit Word Double word Indirect
specification
Constant Others
X, Y, M, L,
SM, F, B,
SB, FX, FY
J\ T, ST, C, D, W,
SD, SW, FD,
R, ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K,
H
E $ J U
(J/U) JP.RECV
GP.RECV
(s)
*2
(d1)
*2
(d2)
*1
*3
Operand: (s)
Device Item Description Setting range Set by
+0 Error completion type
(1) Error completion type (bit 7)
Specify whether to set clock data when completed with an error.
• 0: Clock data at error occurrence is not stored in (s1)+11 and later.
• 1: Clock data at error occurrence is stored in (s1)+11 and later.
0000H
0080H
User
+1 Completion status The completion status is stored upon completion of the instruction.
•0: Normal
• Other than 0: Error (error code)
System
+2 Own station storage
channel
Specify the channel to be used by own station. (Page 1450 Range of available
channel numbers)
1 to 8, 11 to 18 User
+3 Channel used by send
station
The channel number (1 to 8) used by the sending station is stored. 1 to 8 System
+4 Send station network
number
The network number (1 to 239) of the sending station is stored. 1 to 239 System
+5 Sending-station No. The station number of the sending station is stored.
[Ethernet or CC-Link IE Controller Network]
• 1 to 120: Station number (receiving from station number)
[CC-Link IE Field Network]
• 125: Master station
• 1 to 120: Local station, intelligent device station, submaster station
1 to 120, 125 System
+6 Not used
+7 Not used
+8 Arrival monitoring time [CC-Link IE Controller Network or CC-Link IE Field Network]
Specify the monitoring time until completion of processing. The instruction is
completed with an error if it fails to complete within the monitoring time.
•0: 10s
• 1 to 32767: 1 to 32767s
0 to 32767 User
[Ethernet]
Specify the TCP resend timer value or greater for the monitoring time till completion
of processing. The instruction is completed with an error if it fails to complete within
the monitoring time.
• 0 to (TCP resend timer value): The TCP resend timer value is assumed as the
monitoring time.
• (TCP resend timer value + 1) to 16383: (TCP resend timer value + 1) to 16383s
0 to 16383 User
+9 Receive data length The number of data received and stored in (d1) to (d1)+n is stored.
• 0: No receive data
• 1 to 960: Number of words of received data
0 to 960 System
+10 Not used
+11 Clock setting flag The validity status (valid or invalid) of the data in (s)+12 and later is stored.
Note that the data in (s)+12 and later is not cleared even when the instruction is
completed successfully.
• 0: Invalid
• 1: Valid
System