15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
1519
15
■Applicable devices
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
The REQ instruction cannot be executed when the target station is ACPU.
■Control data
Operand Bit Word Double word Indirect
specification
Constant Others
X, Y, M, L,
SM, F, B,
SB, FX, FY
J\ T, ST, C, D, W,
SD, SW, FD,
R, ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $ J U
(J/U) J(P).REQ
G(P).RE
Q
(s1)
*2
(s2)
*2
(d1)
*2
(d2)
*1
*3
Operand: (s1)
Device Item Description Setting range Set by
+0 Error completion type
(1) Error completion type (bit 7)
Specify whether to set data when completed with an error.
• 0: Do not set data in (s1)+11 and later at completion with an error.
• 1: Set data in (s1)+11 and later at completion with an error.
0011H
0091H
User
+1 Completion status The completion status is stored upon completion of the instruction.
•0: Normal
• Other than 0: Error (error code)
System
+2 Own station channel Specify the channel to be used by own station. (Page 1450 Range of available
channel numbers)
1 to 8, 11 to 18 User
+3 Target station CPU type Specify the CPU type of the target station.
• 0000H: Addressed to target station CPU (control CPU)
• 03D0H: Addressed to control system CPU
• 03D1H: Addressed to standby system CPU
• 03D2H: Addressed to system A CPU
• 03D3H: Addressed to system B CPU
• 03E0H: Addressed to multiple CPU No. 1
• 03E1H: Addressed to multiple CPU No. 2
• 03E2H: Addressed to multiple CPU No. 3
• 03E3H: Addressed to multiple CPU No. 4
• 03FFH: Addressed to target station CPU (control CPU)
0000H
03D0H to 03D3H
03E0H to 03E3H
03FFH
User
+4 Target network number Specify the network number of the target station.
• 1 to 239: Network number
1 to 239 User
+5 Target station number Specify the station number of the target station.
(1) Station number specification
[Ethernet or CC-Link IE Controller Network]
• 1 to 120: Station number
[CC-Link IE Field Network]
• 125: Master station
• 126: Master operating station
• 1 to 120: Local station, intelligent device station, submaster station
(2) Group number specification
[Ethernet or CC-Link IE Controller Network]
0081H to 00A0H: All stations with group numbers 0001H to 0020H
(can be specified only for clock data writing)
(3) All-station specification
00FFH: All stations of target network number (broadcast (excluding the own station))
(can be specified only for clock data writing)
1 to 120,
125, 126,
0081H to 00A0H,
00FFH
User