1578
17 CC-LINK IE CONTROLLER NETWORK INSTRUCTIONS
17.1 Remote RUN
*1 If the instruction is executed with group or all stations specification:
For the target station CPU type, specify either 0000H or 03FFH. If the target station is in CC-Link IE Field Network, group specification is
not available. To check that the data has been written successfully in the target station, examine whether the CPU module of the
destination has entered the RUN state.
*2 If the instruction is executed with the control system CPU (03D0H) or standby system CPU (03D1H) specified, it may complete with an
error if system switching occurs in the target station (error code: 4244H, 4248H).
Retry to execute the instruction if it completed with an error due to the above error.
Remote RUN is enabled when the RUN/STOP/RESET switch of the target station CPU module is "RUN."
If the target station CPU module is system protected, remote RUN will fail.
If the target station CPU module has already been remotely stopped or paused from another station, RUN
will fail if (s4) is "Not forcibly executed (0001H)."
Applicable devices
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
Processing details
Remote RUN is executed for the target station CPU module according to the (s4) specification details. The target station is
specified with the target network number (J) or the start I/O number (U) of the own station or node and the target station
number (s2). After completion of request to the target station, the completion device specified by (d) turns on.
The specifiable stations are those with the specified network number that are included in one of the following networks.
Operand Bit Word Double word Indirect
specification
Constant Others
X, Y, M, L,
SM, F, B,
SB, FX, FY
J\ T, S T, C , D , W,
SD, SW, FD,
R, ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $ J U
(J/U) J(P).RRUN  
G(P).RRUN  
Z(P).RRUN 
(s1)
*1

*2
 
(s2)
*1

*2
 
(s3)
*1

*2
 
(s4)
*1

*2
 
(d)
*1

*3
 
CH: Channel
MELSECNET/H
MELSECNET/10
CC-Link IE Controller Network
CC-Link IE Field Network
Ethernet
(s4)
RUN
RRUN
CH8
CHn
CH1
CC-Link IE Controller
Network moduleCPU module CPU module Network module
[Own station] [Target station]