EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 2023

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPX
Appendix 1 Instruction Processing Time
2021
A
ANDDT< When not executed 0.00588
When compared with the specified date: Continuity 2.600 9.400
When compared with the specified date: Non-continuity 2.600 9.600
When compared with the current date: Continuity 4.800 16.200
When compared with the current date: Non-continuity 4.900 15.200
ANDDT>= When not executed 0.00588
When compared with the specified date: Continuity 2.700 9.900
When compared with the specified date: Non-continuity 2.700 9.700
When compared with the current date: Continuity 4.900 14.600
When compared with the current date: Non-continuity 4.900 14.900
ORDT= When not executed 0.00588
When compared with the specified date: Continuity 2.700 9.800
When compared with the specified date: Non-continuity 2.600 9.800
When compared with the current date: Continuity 4.800 15.600
When compared with the current date: Non-continuity 4.800 15.400
ORDT<> When not executed 0.00588
When compared with the specified date: Continuity 2.800 10.000
When compared with the specified date: Non-continuity 2.700 10.100
When compared with the current date: Continuity 4.700 15.900
When compared with the current date: Non-continuity 4.800 15.600
ORDT> When not executed 0.00588
When compared with the specified date: Continuity 2.800 10.000
When compared with the specified date: Non-continuity 2.700 10.000
When compared with the current date: Continuity 4.800 15.600
When compared with the current date: Non-continuity 4.800 15.700
ORDT<= When not executed 0.00588
When compared with the specified date: Continuity 2.700 9.800
When compared with the specified date: Non-continuity 2.600 10.000
When compared with the current date: Continuity 4.900 15.000
When compared with the current date: Non-continuity 4.900 15.000
ORDT< When not executed 0.00588
When compared with the specified date: Continuity 2.800 10.200
When compared with the specified date: Non-continuity 2.700 10.100
When compared with the current date: Continuity 4.800 15.500
When compared with the current date: Non-continuity 4.900 15.400
ORDT>= When not executed 0.00588
When compared with the specified date: Continuity 2.800 9.500
When compared with the specified date: Non-continuity 2.800 9.600
When compared with the current date: Continuity 4.700 14.500
When compared with the current date: Non-continuity 4.700 14.900
LDTM= When compared with the specified time: Continuity 2.900 9.500
When compared with the specified time: Non-continuity 2.900 9.500
When compared with the current time: Continuity 4.700 15.600
When compared with the current time: Non-continuity 4.700 14.900
LDTM<> When compared with the specified time: Continuity 2.600 9.200
When compared with the specified time: Non-continuity 2.600 9.300
When compared with the current time: Continuity 4.900 14.500
When compared with the current time: Non-continuity 4.800 14.500
LDTM> When compared with the specified time: Continuity 2.600 9.200
When compared with the specified time: Non-continuity 2.600 9.300
When compared with the current time: Continuity 4.800 14.600
When compared with the current time: Non-continuity 4.900 14.700
Instruction name Condition Processing time (s)
Minimum Maximum

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals