Appendix 1 Instruction Processing Time
LDTM<= When compared with the specified time: Continuity 2.600 9.200
When compared with the specified time: Non-continuity 2.700 9.200
When compared with the current time: Continuity 4.900 14.500
When compared with the current time: Non-continuity 4.900 14.600
LDTM< When compared with the specified time: Continuity 2.600 9.300
When compared with the specified time: Non-continuity 2.600 9.300
When compared with the current time: Continuity 4.700 14.800
When compared with the current time: Non-continuity 4.900 14.700
LDTM>= When compared with the specified time: Continuity 2.500 9.100
When compared with the specified time: Non-continuity 2.600 9.200
When compared with the current time: Continuity 4.900 14.500
When compared with the current time: Non-continuity 4.800 14.600
ANDTM= When not executed 0.00588
When compared with the specified time: Continuity 2.400 9.100
When compared with the specified time: Non-continuity 2.500 9.200
When compared with the current time: Continuity 4.900 14.600
When compared with the current time: Non-continuity 4.900 14.700
ANDTM<> When not executed 0.00588
When compared with the specified time: Continuity 2.400 9.100
When compared with the specified time: Non-continuity 2.600 9.400
When compared with the current time: Continuity 4.900 14.800
When compared with the current time: Non-continuity 4.900 14.800
ANDTM> When not executed 0.00588
When compared with the specified time: Continuity 2.600 9.400
When compared with the specified time: Non-continuity 2.600 9.500
When compared with the current time: Continuity 4.800 14.700
When compared with the current time: Non-continuity 4.900 14.800
ANDTM<= When not executed 0.00588
When compared with the specified time: Continuity 2.600 9.400
When compared with the specified time: Non-continuity 2.600 9.400
When compared with the current time: Continuity 4.900 15.000
When compared with the current time: Non-continuity 4.900 14.900
ANDTM< When not executed 0.00588
When compared with the specified time: Continuity 2.600 9.500
When compared with the specified time: Non-continuity 2.600 9.600
When compared with the current time: Continuity 4.900 14.700
When compared with the current time: Non-continuity 4.900 14.800
ANDTM>= When not executed 0.00588
When compared with the specified time: Continuity 2.600 9.400
When compared with the specified time: Non-continuity 2.600 9.400
When compared with the current time: Continuity 4.900 14.900
When compared with the current time: Non-continuity 4.800 14.900
ORTM= When not executed 0.00588
When compared with the specified time: Continuity 2.700 9.200
When compared with the specified time: Non-continuity 2.700 9.100
When compared with the current time: Continuity 5.000 14.900
When compared with the current time: Non-continuity 5.000 14.800
ORTM<> When not executed 0.00588
When compared with the specified time: Continuity 2.700 9.200
When compared with the specified time: Non-continuity 2.700 9.200
When compared with the current time: Continuity 5.000 15.000
When compared with the current time: Non-continuity 5.000 15.000
Instruction name Condition Processing time (s)
Minimum Maximum