APPX
Appendix 1 Instruction Processing Time
2025
A
UNIINFRD (n)=1 13.400 20.000
(When the Process
CPU is used:
22.900)
(n)=16 26.100 33.100
(When the Process
CPU is used:
36.800)
S.RTREAD 2.400 5.900
S.RTWRITE 13.500 43.800
LOGTRG 55.700 74.500
LOGTRGR 11.000 18.600
SP.SOCOPEN TCP: Active 15.600 33.800
TCP: Unpassive 15.600 33.800
TCP: Fullpassive 15.600 33.800
UDP 15.600 33.800
SP.SOCCLOSE TCP: Executed from own device 15.300 34.000
TCP: Executed from external device 15.300 34.000
UDP 15.300 34.000
SP.SOCRCV TCP: Minimum amount of data (1 byte) 15.000 36.700
TCP: Maximum amount of data (10238 bytes) 15.000 36.700
UDP: Minimum amount of data (1 byte) 15.200 36.800
UDP: Maximum amount of data (10238 bytes) 15.200 36.800
S.SOCRCVS TCP: Minimum amount of data (1 byte) 15.800 32.000
TCP: Maximum amount of data (10238 bytes) 141.000 180.000
UDP: Minimum amount of data (1 byte) 15.800 32.000
UDP: Maximum amount of data (10238 bytes) 145.000 182.000
SP.SOCSND TCP: Minimum amount of data (1 byte) 18.000 35.400
TCP: Maximum amount of data (10238 bytes) 155.000 180.000
UDP: Minimum amount of data (1 byte) 18.000 35.400
UDP: Maximum amount of data (10238 bytes) 155.000 180.000
SP.SOCCINF 3.100 9.200
SP.SOCCSET 3.300 14.500
SP.SOCRMODE Switching from normal mode to fixed-length mode 4.800 14.200
Switching from fixed-length mode to normal mode 4.800 13.900
S.SOCRDATA Minimum amount of data (1 word) 4.200 10.100
Maximum amount of data (5120 words) 114.400 162.800
SP.ECPRTCL 33.200 39.800
SP.SLMPSND "Read (command: 0401H)" (reading in units of words): Number of read points = 1
point
16.4 41.4
SP.FTPPUT File name + server path string = 32 characters 76.000 80.000
File name + server path string = 64 characters 93.000 97.000
SP.FTPGET File name + server path string = 32 characters 76.000 80.000
File name + server path string = 64 characters 93.000 97.000
PSTOP File name: "P1" 43.000 78.000
POFF File name: "P1" 42.300 77.000
PSCAN File name: "P1" 43.700 78.200
PID 3.900 10.200
S.PIDINIT 1 loop 3.500 7.000
32 loop 53.300 56.900
S.PIDCONT 1 loops (first time) 16.600 18.100
1 loops (second and later) 13.900 19.500
32 loops (first time) 205.000 208.700
32 loops (second and later) 193.300 214.100
Instruction name Condition Processing time (s)
Minimum Maximum