6 BASIC INSTRUCTIONS
6.6 Data Conversion Instructions
381
6
• These instructions convert the 32-bit binary data (0 to 99999999) in the device specified by (s) to BCD 8-digit data, and
store the converted data in the device specified by (d).
(1) Set 0s to the upper 5 bits.
Error code
(SD0)
Description
3401H Data in the device specified by (s) is out of the range, 0 to 99999999.
(s)
(d)
0
BIN 99999999
0
0 0 0 1 0 1 1 1 1 1 0 1 0 1 1 1 1 0 0 0 0 0 1 1 1 1 1 1 1 1
0
BCD 99999999
1
0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1
4
8 218 42184218 4218 42184218 4218 421
×10
7
×10
6
×10
5
×10
4
×10
3
×10
2
×10
1
×10
0
2
31
2
30
2
29
2
28
2
27
2
26
2
25
2
24
2
23
2
22
2
21
2
20
2
19
2
18
2
17
2
16
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BCD
(1)
(s)+1 (Upper 16 bits) (s) (Lower 16 bits)
(d)+1 (Upper 4 digits) (d) (Lower 4 digits)