472
6 BASIC INSTRUCTIONS
6.6 Data Conversion Instructions
Processing details
These instructions turn on the bit, corresponding to the binary value specified by the lower (n) bits in the device specified by
(s), in the device specified by (d)
Specify a value 1 to 8 for (n).
When (n)=0, no processing is performed and the values in the device specified by (d) remain unchanged.
A bit device is treated as 1 bit, and a word device is treated as 16 bits.
Operation error
Error code
(SD0)
Description
3401H The value specified by (n) is out of the range, 0 to 8.
7
01
ON
000000
110
6543210
n=3
(d)
(s)
=6