EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 659

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 APPLICATION INSTRUCTIONS
7.8 String Processing Instructions
657
7
Operation of when SM705 (Number of conversion digits selection) is off
Hexadecimal ASCII data is stored in a fixed number of digits (8 digits) in (d) to (d)+3.
The operation result to be stored in the device specified by (d) is processed as a 8-digit hexadecimal number. Therefore, 0
at the left side of the effective number of digits is processed as "0". (Zero padding)
Ex.
When 03AC625EH is stored in the device specified by (s)
Operation of when SM705 (Number of conversion digits selection) is on
Hexadecimal ASCII data for the number of digits (up to 8 digits) without the leftmost "0" in the effective digits is stored right-
justified in (d).
The following figures show an example of a value of (s) and a value stored in (d).
When the number of digits is less than the maximum number of digits (8 digits), 00H is stored in the end of the string
regardless of the status (on/off) of SM701 (Number of output characters selection). If the end of the string is the lower byte,
00H is also stored in the upper byte.
When the number of digits is equal to the maximum number of digits (8 digits), 00H is stored in (d)+4 when SM701 (Number
of output characters selection) is off. (d)+4 does not change if SM701 (Number of output characters selection) is on.
ASCII : ASCII code (th digit)
(1): 00H is stored in (d)+4 when SM701 (Number of output characters selection) is off. When it is on, the value in (d)+3 remains unchanged.
Value of (s) Data of (d) to (d)+3 Value of (s) Data of (d) to (d)+3
0H to FH The upper byte of (d) is filled with 00H.
(d)+1 and later remain unchanged.
10H to FFH (d)+1 is filled with 00H.
(d)+2 and later remain unchanged.
1000000H to
FFFFFFFH
The upper byte of (d)+3 is filled with 00H. 10000000H to
FFFFFFFFH
(1): (d)+4 is filled with 00H when SM701 (Number of
output characters selection) is off. (d)+4 does not
change if SM701 (Number of output characters
selection) is on.
ASCII : ASCII code (th digit)
b31 b15b16 b0
(s)+1 (s)
BIN 32bit
 
(d)+1
(d)+2
(d)+3
(d)+4
(d)
b15 b0 b7b8
ASCII 8
ASCII 6
ASCII 4
ASCII 2
ASCII 7
ASCII 5
ASCII 3
ASCII 1
00H
(1)
(d)
(d)+1
(d)+2
(d)+3
(d)+4
b15 b0 b7b8
(s)+1 (s)
0 3 AC 625EH
30H (0)
43H (C)
33H (3)
41H (A)
36H (6)32H (2)
45H (E) 35H (5)
00H
(d)+1
(d)+2
(d)+3
(d)
b15 b0 b7b8
ASCII 1
00H
(d)+1
(d)+2
(d)+3
(d)
b15 b0 b7b8
ASCII 2ASCII 1
00H
(d)+1
(d)+2
(d)+3
(d)
b15 b0 b7b8
ASCII 6
ASCII 4
ASCII 2
ASCII 7
ASCII 5
ASCII 3
ASCII 1
00H
(d)+1
(d)+2
(d)+3
(d)+4
(d)
b15 b0 b7b8
ASCII 8
ASCII 6
ASCII 4
ASCII 2
ASCII 7
ASCII 5
ASCII 3
ASCII 1
00H
(1)

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals