750
7 APPLICATION INSTRUCTIONS
7.9 Real Number Instructions
Processing details
These instructions convert the double-precision real number in the device specified by (s) to a single-precision real number,
and store the real number in the device specified by (d).
When an input value is set using the engineering tool, a rounding error may occur. Refer to the following for the precautions
on setting input values using the engineering tool.
Page 49 Precautions
Operation error
Error code
(SD0)
Description
3402H The value input to (s) is -0, a subnormal number, NaN (not a number), or .
3403H The data output from (d) exceeds the following range. (An overflow has occurred.)
|(d)|<2
128
(s)
b63 b49
(-123456.7)
240BHC0FEHD3, D2, D1, D0
b48 b32
(d)
b31 b16
0000H4000H
b15 b0
b31 b16
(-123456.7)
205AH
C71FH
b15 b0
D101, D100
     
SM402
(s) (d)
M0
EDMOVP E-123456.7 D0
DBL2FLT D0 D100