4 SAFETY FB SPECIFICATIONS
4.14 M+SF_TSSEN_R
101
4
Application example
An application example of M+SF_TSSEN_R is shown below.
■ Labels
• Input labels
• Output labels
Variable name Allocated device/label Description
i_bActivate SA\M100 Activation of the safety FB
i_bS_OSSD_In SA\X1000 Light curtain output signal
i_bStartTest StartTest (standard/safety shared label) Start test switch (standard control input)
i_dTestTime K15 Test time of safety sensor
i_bNoExternalTest SA\X1003 Manual sensor test status
i_bS_StartReset SA\X1004 Reset method for the activated safety FB
i_bS_AutoReset SA\X1005 Reset method for the input signal reset to ON
i_bReset SA\X1006 Reset switch
Variable name Allocated device/label Description
o_bReady SA\M200 Status of whether the safety FB is activated or not.
o_bS_OSSD_Out SA\Y1001 Light curtain safety demand considering the test
o_bS_TestOut SA\Y1002 Automatic sensor test request
o_bTestPossible SA\Y1003 Possibility of an automatic test
o_bTestExecuted SA\Y1004 Result of an automatic test
o_bError SA\Y1005 Error flag
o_wDiagCode SA\D1000 Diagnostic code