58
4 SAFETY FB SPECIFICATIONS
4.9 M+SF_MODSEL_R
Error behavior
In the event of an error, the output signals behave as listed below.
For the corrective actions, see the following.
Page 58 List of error codes
List of error codes
Output signal Status
o_bReady ON
o_bS_Mode0Sel to o_bS_Mode7Sel OFF
o_bS_AnyModeSel OFF
o_bError ON
o_wDiagCode
(Hexadecimal)
State name Description, output setting Action
C001H Error Short-circuit The FB detected that two or more i_bS_ModeX=ON. Set only one i_bS_ModeX to ON and set
i_bReset to ON.
Check the connection and wiring related
to i_bReset.
C002H Error Open-circuit The FB detected that all i_bS_ModeX=OFF:
The period following a falling i_bS_ModeX trigger
exceeds i_dModeMonitorTime.
Set only one i_bS_ModeX to ON and set
i_bReset to ON.
Check the connection and wiring related
to i_bReset.
Check the value of
i_dModeMonitorTime.
C003H Reset Error 1 Static i_bReset signal detected in state C001H. Set i_bReset to OFF.
Check the devices and wiring related to
i_bReset.
C004H Reset Error 2 Static i_bReset signal detected in state C002H.
C005H Parameter Error The value of i_dModeMonitorTime is out of range (0 to
60000).
Set a proper value to
i_dModeMonitorTime.
Set i_bReset to ON.
C100H S_SetMode Error Static i_bS_SetMode signal detected with
i_bS_Unlock=ON in state 8005H.
Set i_bS_SetMode to OFF.
Check the devices and wiring related to
i_bReset.